A new aspects for project of subsequent thermal resistance extension at old-timer timbering constructions of wood

Zdeňka Havířová

Ústav základního zpracování dřeva, Mendelova zemědělská a lesnická univerzita v Brně, Zemědělská 1, 613 00 Brno, Česká republika

To ensure the reliability of subsequent thermal resistance extension at old-timer timbering constructions of wood for the period of their supposed service life a more profound analysis of construction is necessary from the aspect of a global thermal/technical evaluation. Service life of these buildings is dependent on temperature and moisture conditions in layers of the building cladding where the wood framework is built in. Temperature/moisture conditions or the corresponding equilibrium moisture content (EMC) of the construction show considerable effects on the functional reliability of the whole building from the viewpoint of mechanical resistance and stability, energy savings and thermal protection and hygiene, health and environment protection.